MASTERYS IP+ RAIL OLI (20-120 kVA)
Key Benefits
• Full Range 20-120 kVA
• IP Protection Degree: IP31 standard
• High Efficiency
• Coated Electronic Boards
• Full Galvanic Isolation
• External Manual Bypass
• (Low Smoke Zero Halogen option)
Socomec’s IP+ Rail (OLI) offers increased energy availability: the system can take inputs from both a 25 kV overhead line as well as a 400V AC mains supply.
As a result, this solution potentially avoids the need for a diesel generator and its associated maintenance, fuel storage and refuelling costs.
The innovative rectifier stage converts the input voltage into a DC voltage that will charge both the UPS battery and supply the input stage of the inverter.
In normal mode*, the upstream voltage of the rectifier corresponds to the transformed single phase voltage of the overhead line. The transformer and voltage stabiliser eliminates voltage sags and surges related to current draw of locomotives. When this voltage is not present or is no longer with intolerance, it is the 3 phase DNO supply which is sent directly to the UPS rectifier.
The inverter converts the DC voltage, provided either from the rectifier output or from the battery in a perfect sinusoidal voltage distributed to the critical loads. The UPS is also equipped with an automatic bypass which allows a no-break transfer of the load directly onto the mains supply in case of overload or faults.
An external manual bypass completes the solution to allow for maintenance of the UPS.
Standard and optional features
Standard electrical features
• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.
Electrical options
• Long-life batteries.
• External battery cabinet (degree of protection up to IP32).
• External temperature sensor.
• Additional battery chargers.
• Additional transformer.
• Parallel kit.
• Cold start.
• ACS synchronization system.
• Neutral creation kit for mains without neutral.
• Tropicalization and anti-corrosion protection for electrical boards.
Standard communication features
• Multilanguage graphic display.
• Dry-contact interface.
• MODBUS/JBUS RTU.
• Embedded LAN interface (web pages, email).
• 2 slots for communication options.
Communication options
• Remote mimic panel.
• Profibus.
• MODBUS TCP.
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.
Remote maintenance
• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC UPS.