> UPS системи SOCOMEC > Трифазен вход / Трифазен изход SOCOMEC

Трифазен вход / Трифазен изход SOCOMEC

DELPHYS MP Elite (80-200 kVA)

Your protection up to 1200 kVA

The solution for

• Data centres
•  Industry
• Telecommunications
• Processes

Advantages

High quality power supply

• The SVM digital modulation (Space Vector Modulation) fitted to the transformer integrated downstream of the inverter allows supply to your installations with:
- precise voltage even when the load between phases is completely unbalanced,
- stable output voltage during significant and quick variations in loads (± 2% in less than 5 ms).
• Active power without derating, for loads with a lagging power factor

and up to 0.9 leading.
• Sinusoidal THDV output voltage < 2 % with linear loads and < 3 % with non-linear loads.
• With sinusoidal voltage for non-linear loads (Crest Factor 3:1).
• A very high short-circuit capacity which facilitates the selection of protective devices for selectivity in the downstream distribution.
• An isolation transformer is installed on the inverter output to ensure complete galvanic isolation between DC circuit and load output.
This insulation also provides a separation between the two inputs when they are supplied by different sources.

High availability

• A fault-tolerant architecture with redundancy of basic functions, such as the ventilation system.
• A variety of architectures for parallel operations, to deal with redundancy, management and changes in power output.
• The ideal solution for grouping with generator sets without using an

excessively large generator.

Battery availability at all times

• An innovative load algorithm which adapts to the environmental conditions and the condition of the battery to increase its life.
• A highly-developed monitoring system, capable of locating and correcting any problems interacting with the charging device.

Cost-effective equipment

• A “clean” IGBT rectifier. The power factor and THDI at the rectifier input are constant whatever the battery charge status (continuous voltage level) and the load rate of the UPS. It eliminates any disturbance on the upstream network (transformer, generator set and distribution).
• The cutting rectifier guarantees the supply of current with an exceptionally low rate of harmonic distortion: THDI < 2.5%.
• Reduced current consumption due to an input power factor of 0.99 without derating, and constant in every situation.

User-friendly operation

• A control panel with graphic display for more ergonomic operation.
• An array of “com-slot” plug-in communication interfaces, for upgrading your operating requirements evolution.

Simplified maintenance

• An advanced diagnostic system.

• A remote access device connected to the remote maintenance centre.
• Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).

STANDARD AND OPTION FEATURES

• Slots for 7 communication cards.
• Backfeed protection: detection circuit
• Standard interface:
- 3 inputs (emergency stop, generating set, battery protection),
- 4 outputs (general alarm, back-up, bypass, preventative maintenance needs).
• Parallel connection up to 6 units.

Electrical options

• BHC Universal.
• EBS (Expert Battery System).
• Flywheel compatible.
• ACS synchronisation system.
• Reinforced IP protection degree.
• Ventilation filters.
• Ventilation failure detection
• Top entry connection

Standard communication features

• Multilanguage graphic display.
• Embedded dry contacts.

Communication options 

• GTS (Graphic Touch Screen).
• Remote panel.
• ADC interface (configurable voltage-free contacts).
• RS232, RS422, RS485 serial port JBUS/MODBUS or PROFIBUS.
• MODBUS TCP interface (JBUS/MODBUS tunneling).
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance

• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC.

  • TECNICAL DATA
  •  

    Sn [kVA] 80 100 120 160 200
    Pn [kW] 64 80 96 128 160
    Input / output 3/3
    Parallel configuration up to 6 units (distributed or centralised bypass)
    Input
    Rated voltage

    380 V - 400 V - 415 V(1)

    Voltage tolerances

    340 to 460 V

    Rated frequency 50/60 Hz
    Frequency tolerance 45 to 65 Hz
    Power factor / THDI 0.99 constant / 2.5 % without filter
    Output
    Rated voltage 380 V - 400 V - 415 V (configurable) (1)
    Voltage tolerance < 1 % (static load), ± 2 % in 5 ms (dynamic load conditions from 0 to 100 %)
    Rated frequency 50/60 Hz
    Frequency tolerance ± 0.2%
    Total output voltage distortion - linear load < 2%
    Total output voltage distortion - non-linear load < 4%
    Short-circuit current Up to 3.5 In
    Overload 150 % for 1 minute, 125 % for 10 minutes
    Crest factor  3:1
    Power factor without derating 0.9 lagging to 0.9 leading
    Bypass
    Rated voltage 380 V - 400 V - 415 V
    Voltage tolerance ± 10% (selectable)
    Rated frequency 50/60 Hz
    Frequency tolerance ± 2%
    Efficiency (TÜV SÜD verified)
    Online mode 94%
    Eco Mode 98%
    Environment
    Operating ambient temperature from 0 °C up to +35 °C (from 15 °C to 25 °C for maximum battery life)
    Relative humidity 0% - 95% without condensation
    Maximum altitude 1000 m without de-rating (3000 m max)
    Acoustic level at 1 m
    (ISO 3746)
    65 dBA 67dBA
    UPS cabinet 
    Dimensions (W x D x H) [mm] 1000 x 800 x 1930 mm
    Weight (2) 740 kg 860 kg 1020 kg
    Degree of protection IP20 (other IP as option)
    Colours RAL 9006
    Standards
    Safety IEC 62040-1-2, IEC 60950
    Performance IEC 62040-3
    EMC IEC 62040-2
    Product declaration CE

     






Разгледай цялото продуктово направление »


Може да Ви интересуват и


BHC - Battery Health Check

FLYWHEEL

СТАНИ ПАРТНЬОР НА

DTS