Line |
N |
Code generator with automatic |
FG NVS 300 AH |
Code generator with manual control |
FG NVS 300 MH |
Maximum power LTP [kVA] |
330.0 |
LTP Maximum Power [kW] |
264.0 |
PRP Rated power [kVA] |
300.0 |
PRP Rated power [kW] |
240.0 |
Rated current [A] |
433.0 |
Frequency [Hz] |
50 |
Voltage [V] |
400 |
The manufacturer of the generator |
Sincro |
Country of production |
Croatia |
Type of generator |
SK250LL |
Power generator (40 ° C, 1000m above sea level) [kVA] |
300.0 |
Generator efficiency [%] |
92.9 |
Voltage stabilization |
AVR Analog |
The level of voltage stabilization [%] |
+/- 1 |
Protection [IP] |
23 |
Insulation class |
H |
Current harmonic distortion THD [%] |
<2.0 |
Reactance X''d [%] |
8.9 |
Engine Manufacturer |
Volvo |
Country of production |
Sweden |
Engine Type |
TAD1341GE |
Net engine power [kW] |
275.0 |
Turnover [r / min] |
1500 |
Speed control |
Electronic |
The classification of |
G3 |
Engine capacity [l] |
12.8 |
Number of cylinders |
6 |
Installation of [V] |
24 |
Cooling |
Volvo Coolant fluid VCS |
The capacity of the cooling system [l] |
44.0 |
Engine Oil |
Shell Rimula R4L |
Oil capacity [l] |
36.0 |
Exhaust Emissions |
Stage II |
Type of fuel |
Diesel (EN 590) |
Fuel consumption for the load of 75% [l / h] |
47.9 |
The fuel consumption for 100% load [l / h] |
62.5 |
Fuel tank capacity [l] |
500 |
Working time for a load of 100% [h] |
8.0 |
The weight of the unit without the fuel [kg] |
2940 |
Dimensions L x W x H [mm] |
3480 x 1300 x 2100 |
Lion Guaranteed sound power level [dB] |
- |
Rated power PRP ISO 8528 |
Specifies the maximum power available with varying load unit in continuous operation. Overload + 10% for up to 1 hour for every 12 hours of operation. Average power consumption within 24 hours should not exceed 70% of the PRP |
Maximum power LTP ISO 8528 |
Specifies the maximum available power generator, with a limit up to 500 hours per year. Average power consumption within 24 hours should not exceed 80% of the LTP maximum uptime - 300h. No overload. Should be used in the event of a mains failure. |
Disclaimer |
All parameters are given for reference conditions: ambient air temperature not higher than 40 ° C and a height of not more than 1000m above sea level |